USE master;
IF NOT EXISTS (SELECT * FROM sys.databases WHERE name = 'teleport') CREATE DATABASE teleport;
USE teleport;
IF NOT EXISTS (SELECT * FROM sysobjects WHERE name='teleport_battery_power' and xtype='U') CREATE TABLE "teleport_battery_power"( "id" int not null identity(1,1), "teleport_hash_id" varchar(32) NOT NULL, "asset_identifier" varchar(128) NOT NULL, "attempt" int NOT NULL, "battery_status" varchar(32) DEFAULT NULL, -- can be "on", "off", "other" or null (see warning and errors in case of 'other') "energy_charged" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "energy_discharged" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "frequency" decimal(7,2) DEFAULT NULL, -- in Hz, nonnegative "active_power" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "reactive_power" decimal(23,3) DEFAULT NULL, -- in var, positive is injecting reactive power to the grid and negative is absorbing reactive power "power_factor" decimal(5, 4) DEFAULT NULL, -- unitless. For capacitive loads (leading power factor, quadrants 2 and 4), the PF sign is positive. For inductive loads (lagging power factor, quadrants 1 and 3), the PF sign is negative. "state_of_charge" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "state_of_health" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "available_energy" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "rated_energy" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "available_active_power_charge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "available_active_power_discharge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "available_reactive_power_inject" decimal(23,3) DEFAULT NULL, -- in var, nonnegative "available_reactive_power_absorb" decimal(23,3) DEFAULT NULL, -- in var, nonnegative "active_power_setpoint_active_power" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "active_power_setpoint_deliver_fcr" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "active_power_setpoint_charge_to_percentage" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "active_power_setpoint_aggregate" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "three_phase_connection_type_high_voltage" varchar(32) DEFAULT NULL, -- can be "wye" or "delta" "ac_voltage_medium_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_current_medium_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "auxiliary_power_active" decimal(23,3) DEFAULT NULL, -- in W, can be null. Negative means consuming, positive generating, will be negative or 0 "auxiliary_power_reactive" decimal(23,3) DEFAULT NULL, -- in Var, can be null. Negative means consuming, positive generating, will be negative or 0 "recent_setpoint_statistics_min" decimal(23,3) DEFAULT NULL, -- in W, can be null "recent_setpoint_statistics_max" decimal(23,3) DEFAULT NULL, -- in W, can be null "recent_setpoint_statistics_active_power_min" decimal(23,3) DEFAULT NULL, -- in W, can be null "recent_setpoint_statistics_active_power_max" decimal(23,3) DEFAULT NULL, -- in W, can be null "recent_setpoint_statistics_reactive_power_min" decimal(23,3) DEFAULT NULL, -- in W, can be null "recent_setpoint_statistics_reactive_power_max" decimal(23,3) DEFAULT NULL, -- in W, can be null "setpoints_confirmed_active_power" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging. "setpoints_confirmed_reactive_power_reactive_power" decimal(23,3) DEFAULT NULL, -- setpoint for "fixedReactivePower" mode, in var. "setpoints_confirmed_reactive_power_power_factor" decimal(5,4) DEFAULT NULL, -- setpoint for "fixedPowerFactor" mode, unitless. "setpoints_confirmed_reactive_power_mode" varchar(32) DEFAULT NULL, -- reactive power control mode, either "fixedReactivePower" or "fixedPowerFactor". "setpoints_confirmed_deliver_fcr" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "setpoints_confirmed_charge_to_percentage" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "setpoints_desired_active_power_cloud" decimal(23,3) DEFAULT NULL, -- in W "setpoints_desired_active_power_active_control" decimal(23,3) DEFAULT NULL, -- in W "setpoints_desired_active_power_grid_operator" decimal(23,3) DEFAULT NULL, -- in W "setpoints_desired_active_power_modbus_server" decimal(23,3) DEFAULT NULL, -- in W "setpoints_desired_reactive_power_cloud_reactive_power" decimal(23,3) DEFAULT NULL, -- setpoint for "fixedReactivePower" mode, in var. "setpoints_desired_reactive_power_cloud_power_factor" decimal(5,4) DEFAULT NULL, -- setpoint for "fixedPowerFactor" mode, unitless. "setpoints_desired_reactive_power_cloud_mode" varchar(32) DEFAULT NULL, -- reactive power control mode, either "fixedReactivePower" or "fixedPowerFactor". "setpoints_desired_reactive_power_grid_operator_reactive_power" decimal(23,3) DEFAULT NULL, -- setpoint for "fixedReactivePower" mode, in var. "setpoints_desired_reactive_power_grid_operator_power_factor" decimal(5,4) DEFAULT NULL, -- setpoint for "fixedPowerFactor" mode, unitless. "setpoints_desired_reactive_power_grid_operator_mode" varchar(32) DEFAULT NULL, -- reactive power control mode, either "fixedReactivePower" or "fixedPowerFactor". "setpoints_desired_charge_to_percentage_cloud" decimal(7,4) DEFAULT NULL, "setpoints_desired_deliver_fcr_cloud" decimal(23,3) DEFAULT NULL, -- in W "setpoints_desired_deliver_fcr_modbus_server" decimal(23,3) DEFAULT NULL, -- in W, can be null. Positive means discharging, negative charging. "setpoints_effective_active_power" decimal(23,3) DEFAULT NULL, -- in W "setpoints_effective_reactive_power_reactive_power" decimal(23,3) DEFAULT NULL, -- setpoint for "fixedReactivePower" mode, in var. "setpoints_effective_reactive_power_power_factor" decimal(5,4) DEFAULT NULL, -- setpoint for "fixedPowerFactor" mode, unitless. "setpoints_effective_reactive_power_mode" varchar(32) DEFAULT NULL, -- reactive power control mode, either "fixedReactivePower" or "fixedPowerFactor". "setpoints_effective_deliver_fcr" decimal(23,3) DEFAULT NULL, -- in W, can be null. Defines the max rate of the droop curve. "warnings" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON aray of string elements. see error codes section "errors" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON array of string elements. see error codes section "cellular_signal_quality" decimal(7,2) DEFAULT NULL, -- RSSI, in dBm, null means there is no up-to-date signal quality data, optional "schedule_complete_until" datetime DEFAULT NULL, -- first gap in the schedule for this asset_identifier "scheduled" bit NOT NULL, -- false for measurements that are not part of the regular reporting interval, eg. directly after command execution and at Teleport initialisation "measured_at" datetime NOT NULL, -- when read-out started "created_at" datetime NOT NULL, -- when written to the table PRIMARY KEY ("id"), INDEX "teleport" ("teleport_hash_id","created_at"), INDEX "teleport_asset" UNIQUE ("teleport_hash_id", "asset_identifier", "measured_at") WITH (IGNORE_DUP_KEY = ON));
IF NOT EXISTS (SELECT NULL FROM SYS.EXTENDED_PROPERTIES WHERE [major_id] = OBJECT_ID('teleport_battery_power') AND [name] = N'version' AND [minor_id] = 0) EXEC sys.sp_addextendedproperty @name=N'version', @value=5, @level0type=N'SCHEMA', @level0name=N'dbo', @level1type=N'TABLE', @level1name=N'teleport_battery_power'ELSE EXEC sys.sp_updateextendedproperty @name=N'version', @value=5, @level0type=N'SCHEMA', @level0name=N'dbo', @level1type=N'TABLE', @level1name=N'teleport_battery_power';
IF NOT EXISTS (SELECT * FROM sysobjects WHERE name='teleport_battery_power_bess' and xtype='U') CREATE TABLE "teleport_battery_power_bess"( "id" int not null identity(1,1), "teleport_hash_id" varchar(32) NOT NULL, "asset_identifier" varchar(128) NOT NULL, "bess_identifier" varchar(128) NOT NULL, "attempt" int NOT NULL, "cell_temperature_min" decimal(6,2) DEFAULT NULL, -- in ºC, min value of all cells "cell_temperature_max" decimal(6,2) DEFAULT NULL, -- in ºC, max value of all cells "room_temperature" decimal(6,2) DEFAULT NULL, -- in ºC, max value of all cells "state_of_charge" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "available_energy" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "available_active_power_charge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "available_active_power_discharge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "three_phase_connection_type_low_voltage" varchar(32) DEFAULT NULL, -- can be "wye" or "delta" "ac_voltage_low_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_current_low_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "warnings" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON aray of string elements. see error codes section "errors" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON array of string elements. see error codes section "scheduled" bit NOT NULL, -- false for measurements that are not part of the regular reporting interval, eg. directly after command execution and at Teleport initialisation "measured_at" datetime NOT NULL, -- when read-out started "created_at" datetime NOT NULL, -- when written to the table PRIMARY KEY ("id"), INDEX "bess" ("bess_identifier","created_at"), INDEX "teleport" ("teleport_hash_id","asset_identifier","created_at"), INDEX "teleport_asset" UNIQUE ("teleport_hash_id", "asset_identifier", "bess_identifier", "measured_at") WITH (IGNORE_DUP_KEY = ON));
IF NOT EXISTS (SELECT * FROM sysobjects WHERE name='teleport_battery_power_bess_rack' and xtype='U') CREATE TABLE "teleport_battery_power_bess_rack"( "id" int not null identity(1,1), "teleport_hash_id" varchar(32) NOT NULL, "asset_identifier" varchar(128) NOT NULL, "bess_identifier" varchar(128) NOT NULL, "rack_identifier" varchar(128) NOT NULL, "attempt" int NOT NULL, "rack_status" varchar(32) DEFAULT NULL, -- can be "on", "off", "other" or null (see warning and errors in case of 'other') "state_of_charge" decimal(7,4) DEFAULT NULL, -- in %, nonnegative, can be null "dc_voltage" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "dc_current" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "cell_temperature_min" decimal(6,2) DEFAULT NULL, -- in ºC, can be null, min value of all cells in the rack "cell_temperature_max" decimal(6,2) DEFAULT NULL, -- in ºC, can be null, max value of all cells in the rack, "cell_temperature_cell_id_min" int DEFAULT NULL, -- can be null, numeric ID of the cell with the lowest temperature in the rack "cell_temperature_cell_id_max" int DEFAULT NULL, -- can be null, numeric ID of the cell with the highest temperature in the rack "cell_voltage_min" decimal(6,3) DEFAULT NULL, -- in V, can be null, min value of all cells in the rack "cell_voltage_max" decimal(6,3) DEFAULT NULL, -- in V, can be null, max value of all cells in the rack "cell_voltage_cell_id_min" int DEFAULT NULL, -- can be null, numeric ID of the cell with the lowest voltage in the rack "cell_voltage_cell_id_max" int DEFAULT NULL, -- can be null, numeric ID of the cell with the highest voltage in the rack "cell_voltage_average" decimal(6,3) DEFAULT NULL, -- in V, can be null, average value of all cells in the rack "scheduled" bit NOT NULL, -- false for measurements that are not part of the regular reporting interval, eg. directly after command execution and at Teleport initialisation "measured_at" datetime NOT NULL, -- when read-out started "created_at" datetime NOT NULL, -- when written to the table PRIMARY KEY ("id"), INDEX "bess_rack" ("rack_identifier","created_at"), INDEX "bess" ("bess_identifier","created_at"), INDEX "teleport" ("teleport_hash_id","asset_identifier","created_at"), INDEX "teleport_asset" UNIQUE ("teleport_hash_id", "asset_identifier", "bess_identifier", "rack_identifier", "measured_at") WITH (IGNORE_DUP_KEY = ON));- The
configurationobject is deprecated and replaced bysetpoints. - Mappings are applied as follows:
configuration_dispatch_power_active_power=setpoints_confirmed_active_power.configuration_deliver_fcr_max_rate=setpoints_confirmed_deliver_fcr.configuration_charge_to_state_percentage=setpoints_confirmed_charge_to_percentage.
- Following properties are renamed and new columns are created
active_power_setpoint_dispatch_powertoactive_power_setpoint_active_poweractive_power_setpoint_charge_to_statetoactive_power_setpoint_charge_to_percentage
USE master;
IF NOT EXISTS (SELECT * FROM sys.databases WHERE name = 'teleport') CREATE DATABASE teleport;
USE teleport;
IF NOT EXISTS (SELECT * FROM sysobjects WHERE name='teleport_battery_power' and xtype='U') CREATE TABLE "teleport_battery_power"( "id" int not null identity(1,1), "teleport_hash_id" varchar(32) NOT NULL, "asset_identifier" varchar(128) NOT NULL, "attempt" int NOT NULL, "battery_status" varchar(32) DEFAULT NULL, -- can be "on", "off", "other" or null (see warning and errors in case of 'other') "energy_charged" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "energy_discharged" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "frequency" decimal(7,2) DEFAULT NULL, -- in Hz, nonnegative "active_power" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "reactive_power" decimal(23,3) DEFAULT NULL, -- in var, positive is injecting reactive power to the grid and negative is absorbing reactive power "power_factor" decimal(5, 4) DEFAULT NULL, -- unitless. For capacitive loads (leading power factor, quadrants 2 and 4), the PF sign is positive. For inductive loads (lagging power factor, quadrants 1 and 3), the PF sign is negative. "state_of_charge" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "state_of_health" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "available_energy" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "rated_energy" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "available_active_power_charge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "available_active_power_discharge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "available_reactive_power_inject" decimal(23,3) DEFAULT NULL, -- in var, nonnegative "available_reactive_power_absorb" decimal(23,3) DEFAULT NULL, -- in var, nonnegative "active_power_setpoint_active_power" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "active_power_setpoint_deliver_fcr" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "active_power_setpoint_charge_to_percentage" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "active_power_setpoint_aggregate" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "three_phase_connection_type_high_voltage" varchar(32) DEFAULT NULL, -- can be "wye" or "delta" "ac_voltage_medium_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_current_medium_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "auxiliary_power_active" decimal(23,3) DEFAULT NULL, -- in W, can be null. Negative means consuming, positive generating, will be negative or 0 "auxiliary_power_reactive" decimal(23,3) DEFAULT NULL, -- in Var, can be null. Negative means consuming, positive generating, will be negative or 0 "setpoints_confirmed_active_power" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging. "setpoints_confirmed_reactive_power_reactive_power" decimal(23,3) DEFAULT NULL, -- setpoint for "fixedReactivePower" mode, in var. "setpoints_confirmed_reactive_power_power_factor" decimal(5,4) DEFAULT NULL, -- setpoint for "fixedPowerFactor" mode, unitless. "setpoints_confirmed_reactive_power_mode" varchar(32) DEFAULT NULL, -- reactive power control mode, either "fixedReactivePower" or "fixedPowerFactor". "setpoints_confirmed_deliver_fcr" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "setpoints_confirmed_charge_to_percentage" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "setpoints_desired_active_power_cloud" decimal(23,3) DEFAULT NULL, -- in W "setpoints_desired_active_power_active_control" decimal(23,3) DEFAULT NULL, -- in W "setpoints_desired_active_power_grid_operator" decimal(23,3) DEFAULT NULL, -- in W "setpoints_desired_active_power_modbus_server" decimal(23,3) DEFAULT NULL, -- in W "setpoints_desired_reactive_power_cloud_reactive_power" decimal(23,3) DEFAULT NULL, -- setpoint for "fixedReactivePower" mode, in var. "setpoints_desired_reactive_power_cloud_power_factor" decimal(5,4) DEFAULT NULL, -- setpoint for "fixedPowerFactor" mode, unitless. "setpoints_desired_reactive_power_cloud_mode" varchar(32) DEFAULT NULL, -- reactive power control mode, either "fixedReactivePower" or "fixedPowerFactor". "setpoints_desired_reactive_power_grid_operator_reactive_power" decimal(23,3) DEFAULT NULL, -- setpoint for "fixedReactivePower" mode, in var. "setpoints_desired_reactive_power_grid_operator_power_factor" decimal(5,4) DEFAULT NULL, -- setpoint for "fixedPowerFactor" mode, unitless. "setpoints_desired_reactive_power_grid_operator_mode" varchar(32) DEFAULT NULL, -- reactive power control mode, either "fixedReactivePower" or "fixedPowerFactor". "setpoints_desired_charge_to_percentage_cloud" decimal(7,4) DEFAULT NULL, "setpoints_desired_deliver_fcr_cloud" decimal(23,3) DEFAULT NULL, -- in W "setpoints_effective_active_power" decimal(23,3) DEFAULT NULL, -- in W "setpoints_effective_reactive_power_reactive_power" decimal(23,3) DEFAULT NULL, -- setpoint for "fixedReactivePower" mode, in var. "setpoints_effective_reactive_power_power_factor" decimal(5,4) DEFAULT NULL, -- setpoint for "fixedPowerFactor" mode, unitless. "setpoints_effective_reactive_power_mode" varchar(32) DEFAULT NULL, -- reactive power control mode, either "fixedReactivePower" or "fixedPowerFactor". "warnings" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON aray of string elements. see error codes section "errors" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON array of string elements. see error codes section "schedule_complete_until" datetime DEFAULT NULL, -- first gap in the schedule for this asset_identifier "scheduled" bit NOT NULL, -- false for measurements that are not part of the regular reporting interval, eg. directly after command execution and at Teleport initialisation "measured_at" datetime NOT NULL, -- when read-out started "created_at" datetime NOT NULL, -- when written to the table PRIMARY KEY ("id"), INDEX "teleport" ("teleport_hash_id","created_at"), INDEX "teleport_asset" UNIQUE ("teleport_hash_id", "asset_identifier", "measured_at") WITH (IGNORE_DUP_KEY = ON));
IF NOT EXISTS (SELECT NULL FROM SYS.EXTENDED_PROPERTIES WHERE [major_id] = OBJECT_ID('teleport_battery_power') AND [name] = N'version' AND [minor_id] = 0) EXEC sys.sp_addextendedproperty @name=N'version', @value=4, @level0type=N'SCHEMA', @level0name=N'dbo', @level1type=N'TABLE', @level1name=N'teleport_battery_power'ELSE EXEC sys.sp_updateextendedproperty @name=N'version', @value=4, @level0type=N'SCHEMA', @level0name=N'dbo', @level1type=N'TABLE', @level1name=N'teleport_battery_power';
IF NOT EXISTS (SELECT * FROM sysobjects WHERE name='teleport_battery_power_bess' and xtype='U') CREATE TABLE "teleport_battery_power_bess"( "id" int not null identity(1,1), "teleport_hash_id" varchar(32) NOT NULL, "asset_identifier" varchar(128) NOT NULL, "bess_identifier" varchar(128) NOT NULL, "attempt" int NOT NULL, "cell_temperature_min" decimal(6,2) DEFAULT NULL, -- in ºC, min value of all cells "cell_temperature_max" decimal(6,2) DEFAULT NULL, -- in ºC, max value of all cells "room_temperature" decimal(6,2) DEFAULT NULL, -- in ºC, max value of all cells "state_of_charge" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "available_energy" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "available_active_power_charge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "available_active_power_discharge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "three_phase_connection_type_low_voltage" varchar(32) DEFAULT NULL, -- can be "wye" or "delta" "ac_voltage_low_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_current_low_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "warnings" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON aray of string elements. see error codes section "errors" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON array of string elements. see error codes section "scheduled" bit NOT NULL, -- false for measurements that are not part of the regular reporting interval, eg. directly after command execution and at Teleport initialisation "measured_at" datetime NOT NULL, -- when read-out started "created_at" datetime NOT NULL, -- when written to the table PRIMARY KEY ("id"), INDEX "bess" ("bess_identifier","created_at"), INDEX "teleport" ("teleport_hash_id","asset_identifier","created_at"), INDEX "teleport_asset" UNIQUE ("teleport_hash_id", "asset_identifier", "bess_identifier", "measured_at") WITH (IGNORE_DUP_KEY = ON));
IF NOT EXISTS (SELECT * FROM sysobjects WHERE name='teleport_battery_power_bess_rack' and xtype='U') CREATE TABLE "teleport_battery_power_bess_rack"( "id" int not null identity(1,1), "teleport_hash_id" varchar(32) NOT NULL, "asset_identifier" varchar(128) NOT NULL, "bess_identifier" varchar(128) NOT NULL, "rack_identifier" varchar(128) NOT NULL, "attempt" int NOT NULL, "dc_voltage" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "dc_current" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "scheduled" bit NOT NULL, -- false for measurements that are not part of the regular reporting interval, eg. directly after command execution and at Teleport initialisation "measured_at" datetime NOT NULL, -- when read-out started "created_at" datetime NOT NULL, -- when written to the table PRIMARY KEY ("id"), INDEX "bess_rack" ("rack_identifier","created_at"), INDEX "bess" ("bess_identifier","created_at"), INDEX "teleport" ("teleport_hash_id","asset_identifier","created_at"), INDEX "teleport_asset" UNIQUE ("teleport_hash_id", "asset_identifier", "bess_identifier", "rack_identifier", "measured_at") WITH (IGNORE_DUP_KEY = ON));USE master;
IF NOT EXISTS (SELECT * FROM sys.databases WHERE name = 'teleport') CREATE DATABASE teleport;
USE teleport;
IF NOT EXISTS (SELECT * FROM sysobjects WHERE name='teleport_battery_power' and xtype='U') CREATE TABLE "teleport_battery_power"( "id" int not null identity(1,1), "teleport_hash_id" varchar(32) NOT NULL, "asset_identifier" varchar(128) NOT NULL, "attempt" int NOT NULL, "battery_status" varchar(32) DEFAULT NULL, -- can be "on", "off", "other" or null (see warning and errors in case of 'other') "energy_charged" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "energy_discharged" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "frequency" decimal(7,2) DEFAULT NULL, -- in Hz, nonnegative "active_power" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "reactive_power" decimal(23,3) DEFAULT NULL, -- in var, positive is injecting reactive power to the grid and negative is absorbing reactive power "state_of_charge" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "state_of_health" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "available_energy" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "rated_energy" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "available_active_power_charge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "available_active_power_discharge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "available_reactive_power_inject" decimal(23,3) DEFAULT NULL, -- in var, nonnegative "available_reactive_power_absorb" decimal(23,3) DEFAULT NULL, -- in var, nonnegative "active_power_setpoint_dispatch_power" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "active_power_setpoint_deliver_fcr" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "active_power_setpoint_charge_to_state" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "active_power_setpoint_aggregate" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging "three_phase_connection_type_high_voltage" varchar(32) DEFAULT NULL, -- can be "wye" or "delta" "ac_voltage_medium_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_medium_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_current_medium_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_medium_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "auxiliary_power_active" decimal(23,3) DEFAULT NULL, -- in W, can be null. Negative means consuming, positive generating, will be negative or 0 "auxiliary_power_reactive" decimal(23,3) DEFAULT NULL, -- in Var, can be null. Negative means consuming, positive generating, will be negative or 0 "configuration_dispatch_power_active_power" decimal(23,3) DEFAULT NULL, -- in W, positive means discharging, negative charging. When dispatchPower is null but the battery system does not support stand-by mode, the Teleport will send a schedule with 0 W to the asset, while the reported dispatchPower is null. "configuration_deliver_fcr_max_rate" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "configuration_charge_to_state_percentage" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "warnings" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON aray of string elements. see error codes section "errors" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON array of string elements. see error codes section "schedule_complete_until" datetime DEFAULT NULL, -- first gap in the schedule for this asset_identifier "scheduled" bit NOT NULL, -- false for measurements that are not part of the regular reporting interval, eg. directly after command execution and at Teleport initialisation "measured_at" datetime NOT NULL, -- when read-out started "created_at" datetime NOT NULL, -- when written to the table PRIMARY KEY ("id"), INDEX "teleport" ("teleport_hash_id","created_at"), INDEX "teleport_asset" UNIQUE ("teleport_hash_id", "asset_identifier", "measured_at") WITH (IGNORE_DUP_KEY = ON));
IF NOT EXISTS (SELECT NULL FROM SYS.EXTENDED_PROPERTIES WHERE [major_id] = OBJECT_ID('teleport_battery_power') AND [name] = N'version' AND [minor_id] = 0) EXEC sys.sp_addextendedproperty @name=N'version', @value=3, @level0type=N'SCHEMA', @level0name=N'dbo', @level1type=N'TABLE', @level1name=N'teleport_battery_power'ELSE EXEC sys.sp_updateextendedproperty @name=N'version', @value=3, @level0type=N'SCHEMA', @level0name=N'dbo', @level1type=N'TABLE', @level1name=N'teleport_battery_power';
IF NOT EXISTS (SELECT * FROM sysobjects WHERE name='teleport_battery_power_bess' and xtype='U') CREATE TABLE "teleport_battery_power_bess"( "id" int not null identity(1,1), "teleport_hash_id" varchar(32) NOT NULL, "asset_identifier" varchar(128) NOT NULL, "bess_identifier" varchar(128) NOT NULL, "attempt" int NOT NULL, "cell_temperature_min" decimal(6,2) DEFAULT NULL, -- in ºC, min value of all cells "cell_temperature_max" decimal(6,2) DEFAULT NULL, -- in ºC, max value of all cells "room_temperature" decimal(6,2) DEFAULT NULL, -- in ºC, max value of all cells "state_of_charge" decimal(7,4) DEFAULT NULL, -- in %, nonnegative "available_energy" decimal(23,3) DEFAULT NULL, -- in Wh, nonnegative "available_active_power_charge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "available_active_power_discharge" decimal(23,3) DEFAULT NULL, -- in W, nonnegative "three_phase_connection_type_low_voltage" varchar(32) DEFAULT NULL, -- can be "wye" or "delta" "ac_voltage_low_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_voltage_low_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "ac_current_low_voltage_phase_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_phase_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_phase_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_line_l1" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_line_l2" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "ac_current_low_voltage_line_l3" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "warnings" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON aray of string elements. see error codes section "errors" nvarchar(4000) DEFAULT NULL, -- if not null, will contain a JSON array of string elements. see error codes section "scheduled" bit NOT NULL, -- false for measurements that are not part of the regular reporting interval, eg. directly after command execution and at Teleport initialisation "measured_at" datetime NOT NULL, -- when read-out started "created_at" datetime NOT NULL, -- when written to the table PRIMARY KEY ("id"), INDEX "bess" ("bess_identifier","created_at"), INDEX "teleport" ("teleport_hash_id","asset_identifier","created_at"), INDEX "teleport_asset" UNIQUE ("teleport_hash_id", "asset_identifier", "bess_identifier", "measured_at") WITH (IGNORE_DUP_KEY = ON));
IF NOT EXISTS (SELECT * FROM sysobjects WHERE name='teleport_battery_power_bess_rack' and xtype='U') CREATE TABLE "teleport_battery_power_bess_rack"( "id" int not null identity(1,1), "teleport_hash_id" varchar(32) NOT NULL, "asset_identifier" varchar(128) NOT NULL, "bess_identifier" varchar(128) NOT NULL, "rack_identifier" varchar(128) NOT NULL, "attempt" int NOT NULL, "dc_voltage" decimal(23,3) DEFAULT NULL, -- in V, nonnegative "dc_current" decimal(23,3) DEFAULT NULL, -- in A, delivering to the grid is a positive value "scheduled" bit NOT NULL, -- false for measurements that are not part of the regular reporting interval, eg. directly after command execution and at Teleport initialisation "measured_at" datetime NOT NULL, -- when read-out started "created_at" datetime NOT NULL, -- when written to the table PRIMARY KEY ("id"), INDEX "bess_rack" ("rack_identifier","created_at"), INDEX "bess" ("bess_identifier","created_at"), INDEX "teleport" ("teleport_hash_id","asset_identifier","created_at"), INDEX "teleport_asset" UNIQUE ("teleport_hash_id", "asset_identifier", "bess_identifier", "rack_identifier", "measured_at") WITH (IGNORE_DUP_KEY = ON));